How To Move A Shower Drain In A Concrete Floor
Moving a shower drain in a concrete floor requires breaking up the concrete and digging a new pipe trench. With the right power tools, this job isn't too complicated.
Read MoreHunker uses a knowledgeable team of editors, writers, and experts to create all our content. We dive deep into the ever-evolving conversations surrounding home improvement and design, striving to deliver the most current and helpful tips, strengthened by expert takes and tutorials from our talented team.
As we cover many fields of expertise, we make it a priority to ensure every beat remains fresh and comprehensive. Additional information on our editorial process available here.
Moving a shower drain in a concrete floor requires breaking up the concrete and digging a new pipe trench. With the right power tools, this job isn't too complicated.
Read MoreA NEMA 6-15 plug is for a 15-amp, 240-volt circuit and is generally used for office equipment and some air conditioners. The manufacturer recommends using 14-gauge, two conductor cable, but it's safer to upgrade this to 12-gauge. Don't forget to identify the white wire as a hot wire, not neutral.
Read MoreA leaking freezer most likely indicates a bad seal around the freezer door or rom the defrost heater.
Read MoreA 220-volt thermostat, or a line-voltage thermostat, connects directly to the wires powering the heater rather than to low-voltage wires from a transformer.
Read MoreMany people want to know how to charge a refrigeration system after their system starts to fail. Unfortunately, this is a very technical task and professionals are usually required to handle the task. In fact, the EPA requires certified professionals to change refrigerants in many systems.
Read MoreA float switch prevents flooding. An air conditioner includes a normally closed float switch, which turns off the system if the condensate drain clogs and water overfills the drip pan. A bilge or sump pump has a normally open float switch, which turns on the pump when the water level rises above a set point.
Read MoreAn air conditioner uses relays to switch the system's high-voltage parts on and off. The relay contains a low-voltage coil and a high-voltage switch, sometimes called "contact points." When the thermostat switches on, a low-voltage signal energizes the appropriate relay.
Read MoreMost homes with an air conditioning system manufactured before January 1, 2010 use R-22 as the refrigerant. The AC compressor circulates the refrigerant through the system's pipes, metering devices and coils. AC systems with a low R-22 charge do not perform at peak efficiency.
Read MoreAn azeotrope refrigerant blends multiple refrigerant compounds to form a single refrigerant. Most refrigerant blends boil at different rates and require complete evacuation before adding a full charge.
Read MoreA hopper gun sprays popcorn-style drywall texture on ceilings. Popcorn texture hides the ceiling's drywall joints, screw holes and any slight imperfections in the drywall's surface. Popcorn gives the ceiling a uniform, uninterrupted surface. Adjusting the nozzle on a hopper gun changes the look of the texture.
Read MoreA hot tub's water should have a pH level between 7.2 and 7.8, with an ideal range between 7.4 and 7.6. Water with a low pH level corrodes the hot tub's metal parts, heater and the seals. Low pH also causes skin irritation. Hot tub water with low pH has a high acidic level.
Read MoreA rotary switch connects several devices to an electric source. The electricity enters the rotary switch's input terminal and the switch sends electricity to the output terminal selected. Some rotary switches contain more than one circuit. These contain two or more input terminals, called "poles,"
Read MoreLarge electric motors with a high starting torque, like an air conditioner's compressor motor, often use a start capacitor kit. A start capacitor kit contains a start capacitor, relay and wires. The start capacitor gives the motor's windings an electric boost during the start-up phase.
Read MoreTechnicians should test a well pump's control box before pulling a nonworking pump from the well. When the water tank's pressure switch detects low water pressure, its switch closes, which turns on the electricity to the control box.
Read MoreA motor fails when its windings short to ground, short to each other, or open--a break in the winding's wire. The wire in the windings use an insulating covering as an isolation barrier. If the winding's insulation wears away near the motor's case, the bare-wire winding shorts to ground.
Read MoreLow-voltage transformers operate many household appliances, from doorbells to air-conditioning systems. A low-voltage transformer taps into a home's high-voltage power supply and produces a safe, low-voltage electrical feed.
Read MoreMany household appliances use 220-volt switches. These switches, commonly found connected to a pool's pump motor and some air conditioning units, connect to four hot wires. Two wires feed the switch and two wires connect to the appliance.
Read MoreDoorbell systems with two doorbell switches use six wires. Two wires exit a transformer and two wires travel to each doorbell switch. The transformer supplies a low-voltage power supply for the home's centralized alarm systems, including the doorbell and sometimes fire-safety systems.
Read MoreFreon, Dupont's trademarked name for CFC and HCFC refrigerants, has become a generic name for all refrigerants. Refrigerators manufactured before 1995 usually contained R-12, a CFC, as a refrigerant. Only EPA certified technicians can buy R-12.
Read More