How to Turn on a Home Radiator

Hunker may earn compensation through affiliate links in this story. Learn more about our affiliate and product review process here.
Image Credit: Marc_Osborne/iStock/GettyImages

Turning on your home radiator isn't a challenging procedure, but if it doesn't heat up, troubleshooting depends on what type of heating system you have and not the power type as an electric or a gas radiator heater will still operate much the same, but water and steam radiators do not. If you have a water-circulating system, which is more modern, you may have to turn on the circulating pump. There may also be air in the line, which you can bleed out.

Advertisement

If you have an older steam system (also known as a boiler radiator), the problem is usually with the air vent located on the side of the radiator. It's supposed to close when steam enters the radiator and open again when you turn the radiator off, but sometimes it malfunctions.

Video of the Day

Video of the Day

Turning on Water-Circulating Systems

Turn on a water-circulating radiator by rotating the control valve counterclockwise to open it. This valve must be open all the way for the radiator to reach its maximum temperature.

Advertisement

Look for a bleed valve if the radiator doesn't get hot. This valve is usually located on the opposite side of the radiator from the control valve, and it's always near the top of the radiator. You can open some valves with a screwdriver or socket wrench, but some require a special bleeder key, available at hardware stores. Keep your face and fingers away from the bleed valve when you open it as escaping water can be dangerously hot.

Advertisement

Hold a small container under the valve when you open it. Any air that is in the radiator will escape, followed by a stream of hot water. Close the valve when water flows continuously. Check the circulation pump if none of your radiators are heating up. This pump is usually designed to come on automatically, but the breaker controlling it may have tripped. If so, reset the breaker.

Turning on Hydronic Baseboard Systems

Hydronic baseboard heaters function in the same way as radiators in a water-circulating system. The bleed valve is located on a horizontal section of the water pipe that passes through the heater, usually to the side of the heating fins.

Advertisement

Troubleshooting Steam Radiators

Open the radiator's control valve all the way. It's worth noting that the controls for steam radiators must be all the way open or all the way closed; you cannot lower the heat output by partially closing the valve. If the radiator doesn't heat up, look for an air vent on the side of the radiator. The vent is metal, and it's usually cone-shaped. The radiator won't get hot if the air vent is clogged or malfunctioning or if it's not positioned vertically and right side up. There is an easy way to test the valve for blockage or malfunction.

Advertisement

Advertisement

Turn off the control valve and wait for the radiator to cool down. Unscrew the air vent with a wrench; then turn the system on and allow it to heat up and pressurize. Keep your face and fingers away from the air vent when you unscrew it as the escaping steam can easily scald skin. Make sure nothing is near the opening of the air vent; then open the radiator control valve. Steam should come out of the vent opening, which indicates that the air valve is the problem. Turn off the control valve before proceeding. If steam does not come out of the vent opening, you probably need to replace the control valve.

Advertisement

Clean the air vent by immersing it in vinegar overnight. If it has several coats of paint on it, try cleaning it with mineral spirits and a stiff brush. Empty, rinse, and dry the vent thoroughly. Wrap the threads (on the nipple that threads into the radiator) with pipe thread tape and reinstall the vent, tightening it until it's snug but not too tight. Make sure the vent is perfectly vertical. Open the radiator's control valve all the way. If the radiator still doesn't heat up when the system is running, replace the air vent.

Advertisement

Advertisement

references